Cable ducting

Overview

Optimized cable trough, stable cover design, and multi-specification cable arrangement.

  • Efficient cable arrangement design: New separation trough structure, more neat cable arrangement, improved maintenance efficiency.
  • Easy to open cover: Optimized snap design, more stable cover installation, easy to remove and replace.
  • Multiple size specifications: Provide a variety of sizes from small equipment to large cabinets to meet diverse needs.

Key advantages

Flame-Retardant PVC Material (UL94 V-0)


Provides excellent fire resistance for electrical cabinet applications.

Precision Engineering for Quick Assembly


Snap-on covers, side slots, and pre-punched mounting holes reduce labor time

Optimal Cable Routing & Separation


Prevents cross-talk and electromagnetic interference (EMI), improving electrical performance and system safety.

Durability in Harsh Environments


Resists high temperatures, UV exposure, impact, and chemicals.

Compliance & Environmental Assurance


RoHS and REACH compliant, supporting eco-responsible sourcing.

Global Sourcing Flexibility


Compatible with multiple naming conventions like

kabel duct pvc

,

pvc cable duct

, and

duct kabel pvc

, suitable for international markets.

Models & specifications

Cable Ducting 4R 2

Leipole Insulated PVC Wiring Ducts Narrow Slotted Trunking PVC Slotted Wiring Duct for Industrial Wiring Management PVC Slotted Wiring Duct Leipole Insulated PVC Wiring Ducts Narrow Slotted Trunking

wdt_ID wdt_created_by wdt_created_at wdt_last_edited_by wdt_last_edited_at Model Duct Size WxH(mm) Q(mm) P(mm) Base Length Pcs/Package
1 Kiva 03/07/2025 07:12 AM Kiva 03/07/2025 07:12 AM 4R2525 25X25 4 6 Small 2 Meters 100 pcs
2 Kiva 03/07/2025 07:12 AM Kiva 03/07/2025 07:12 AM 4R2530 25X30 4 6 Small 50 pcs
3 Kiva 03/07/2025 07:12 AM Kiva 03/07/2025 07:12 AM 4R2535 25X35 4 6 Small 50 pcs
4 Kiva 03/07/2025 07:12 AM Kiva 03/07/2025 07:12 AM 4R2540 25X40 4 6 Small 50 pcs
5 Kiva 03/07/2025 07:12 AM Kiva 03/07/2025 07:12 AM 4R2545 25X45 4 6 Small 50pcs
6 Kiva 03/07/2025 07:12 AM Kiva 03/07/2025 07:12 AM 4R2550 25X50 4 6 Small 50 pcs
7 Kiva 03/07/2025 07:12 AM Kiva 03/07/2025 07:12 AM 4R2560 25X60 4 6 Small 40pcs
8 Kiva 03/07/2025 07:12 AM Kiva 03/07/2025 07:12 AM 4R2565 25X65 4 6 Small 40 pcs
9 Kiva 03/07/2025 07:12 AM Kiva 03/07/2025 07:12 AM 4R2580 25X80 4 6 Small 30 pcs
10 Kiva 03/07/2025 07:12 AM Kiva 03/07/2025 07:12 AM 4R3030 30X30 4 6 Small 60 pcs
Model Duct Size WxH(mm) Q(mm) P(mm) Base Length Pcs/Package

Cable Ducting

Ideal for small or medium-sized enclosures. ● Space-efficient design ● Handles 8–24 cables per plate ● IP-rated cable sealing with reduced panel cutout

wdt_ID wdt_created_by wdt_created_at wdt_last_edited_by wdt_last_edited_at Model Duct Size WxH(mm) Q(mm) P(mm) Base Length Pcs/Package
1 Kiva 03/07/2025 07:45 AM Kiva 03/07/2025 07:45 AM 8R2525 25X25 8 10 Small 2 Meters 100 pcs
2 Kiva 03/07/2025 07:45 AM Kiva 03/07/2025 07:45 AM 8R2530 25X30 8 10 Small 2 Meters 50 pcs
3 Kiva 03/07/2025 07:45 AM Kiva 03/07/2025 07:45 AM 8R2535 25X35 8 10 Small 2 Meters 50 pcs
4 Kiva 03/07/2025 07:45 AM Kiva 03/07/2025 07:45 AM 8R2540 25X40 8 10 Small 2 Meters 50 pcs
5 Kiva 03/07/2025 07:45 AM Kiva 03/07/2025 07:45 AM 8R2545 25X45 8 10 Small 2 Meters 50 pcs
6 Kiva 03/07/2025 07:45 AM Kiva 03/07/2025 07:45 AM 8R2550 25X50 8 10 Small 2 Meters 50 pcs
7 Kiva 03/07/2025 07:45 AM Kiva 03/07/2025 07:45 AM 8R2560 25X60 8 10 Small 2 Meters 40 pcs
8 Kiva 03/07/2025 07:45 AM Kiva 03/07/2025 07:45 AM 8R2565 25X65 8 10 Small 2 Meters 40 pcs
9 Kiva 03/07/2025 07:45 AM Kiva 03/07/2025 07:45 AM 8R2580 25X80 8 10 Small 2 Meters 30 pcs
10 Kiva 03/07/2025 07:45 AM Kiva 03/07/2025 07:45 AM 8R3030 30X30 8 10 Small 2 Meters 60 pcs
Model Duct Size WxH(mm) Q(mm) P(mm) Base Length Pcs/Package

Wiring duct series

5R series slotted wiring duct

LEIPOLE 5R series wiring duct is made of lead-free rigid PVC with UL94 V-0 flammability rating. 54 sizes from 25×25 mm to 100×100 mm, with Q 6 mm / P 6.5 mm slot design, DIN 43 659 mounting holes, supplied as duct and cover in 2 m lengths.

All 54 sizes
ModelDuct size W×H (mm)Q (mm)P (mm)Pcs / package (2 m)
5R252525×2566.5100
5R253025×3066.550
5R253525×3566.550
5R254025×4066.550
5R254525×4566.550
5R255025×5066.550
5R256025×6066.540
5R256525×6566.540
5R258025×8066.530
5R303030×3066.560
5R304030×4066.550
5R305030×5066.550
5R306030×6066.540
5R308030×8066.530
5R333333×3366.550
5R334533×4566.550
5R336533×6566.540
5R3310033×10066.530
5R353035×3066.550
5R353535×3566.550
5R355035×5066.550
5R356035×6066.540
5R358035×8066.530
5R3510035×10066.528
5R404040×4066.550
5R405040×5066.550
5R406040×6066.540
5R408040×8066.530
5R4010040×10066.528
5R454545×4566.540
5R455045×5066.540
5R456045×6066.532
5R456545×6566.532
5R458045×8066.530
5R505050×5066.540
5R506050×6066.532
5R508050×8066.530
5R5010050×10066.524
5R558055×8066.524
5R604060×4066.530
5R605060×5066.530
5R606060×6066.524
5R608060×8066.524
5R6010060×10066.520
5R656565×6566.524
5R7010070×10066.516
5R805080×5066.530
5R806080×6066.524
5R808080×8066.516
5R8010080×10066.516
5R10050100×5066.520
5R10060100×6066.516
5R10080100×8066.516
5R100100100×10066.512
All 1 model pages

Applications

LEIPOLE’s cable ducting solutions are trusted across a variety of industries and use cases:

  • Control Panels & Switchgear Cabinets


    Clean routing and structured wiring for automation and distribution.

  • Factory Automation Systems


    Organized low-voltage and control cable layouts.

  • Telecom & Data Infrastructure


    Secure cable paths in server racks and BMS enclosures.

  • OEM Machine Panels


    Efficient wiring management in CNC, textile, or packaging machines.

  • Building Electrical Systems


    Used in smart buildings for concealed cable management (e.g.,

    electrical trunking

    ).

Basic knowledge

What Is the Difference Between Cable Ducting and Cable Trunking?

While the terms are often used interchangeably, technically:

  • Cable ducting

    often refers to plastic (PVC) systems used within enclosures or cabinets.

  • Cable trunking

    may refer to surface-mounted systems used in building interiors or industrial walls.

Both serve to route and protect wires but differ in form factor, load-bearing capacity, and aesthetic integration.

Regional Terminology Matters

Terms like

ducting kabel

or

kabel duct pvc

are frequently used in Southeast Asia and Europe, where electrical standards or language-specific catalogs vary. At LEIPOLE, we localize support and offer matching product specifications to ensure seamless procurement.

Frequently asked questions

Q1: Are LEIPOLE cable ducts flame-retardant?


Yes, all LEIPOLE ducts are made from UL94 V-0 flame-retardant PVC material, suitable for industrial cabinet use.

Q2: Can I order custom colors or profiles?


Absolutely. We support OEM/ODM for color matching, company branding, or unique profiles.

Q3: Do you provide datasheets and 3D files?


Yes, technical datasheets and 3D STEP files are available upon request.

Q4: What’s the difference between wire duct and cable duct?


Functionally similar, but “wire duct” is typically used in the U.S. market, while “cable duct” is more common in Europe/Asia.

Q5: Can I use pvc cable duct in outdoor applications?


Standard PVC is not UV-rated, but we offer UV-stabilized options for outdoor or high-temperature environments.

How does a DIN rail mount cable ducting system simplify panel wiring?

DIN rail mount ducting clips directly onto standard rails, keeping wires organized and accessible without extra brackets.

Why choose flame-retardant PVC cable ducting for industrial panels?

Flame-retardant PVC resists ignition and slows fire spread, ensuring safety in high-heat or electrical fault conditions.

What are the advantages of multi-compartment cable ducting for control cabinets?

Multi-compartment ducts separate power, signal, and data cables—reducing interference and making maintenance more efficient.

When is IP65 cable ducting necessary?

Use IP65-rated ducting in outdoor or wash-down environments to keep moisture and dust out of critical wiring.

How do low-profile cable ducting solutions benefit tight spaces?

Low-profile ducts maximize usable space inside cabinets and enclosures, offering neat routing where height is limited.

Product inquiry

Selection & support

Selecting LEIPOLE cable ducting

Match duct size, slot pattern and material to the wiring in your panel.

What sizes of PVC cable duct does LEIPOLE supply?

The 4R and 5R slotted wiring ducts run from 25×25 mm to 100×100 mm and the 8R from 25×25 mm to 100×120 mm, in 2 m lengths with the pack quantity listed per model. The R series is a solid-wall duct without slots. All are flame-retardant PVC rated UL94 V-0 with a snap-on cover.

Check technical documents

How do 4R, 5R and 8R slotted ducts differ?

They differ in slot width Q and slot pitch P: 4R has Q 4–4.5 mm and P 6–6.5 mm, 5R has Q 6 mm and P 6.5 mm, and 8R has Q 8 mm and P 10 mm. Narrow, close slots suit fine control wiring that leaves the duct at many points; wider slots suit larger cables.

Confirm the series

How do I size cable ducting for a control panel?

Choose a duct whose cross-section holds the cable bundle with room to spare, so heat can escape, cables can be added later and the cover still closes, and follow the fill limits in your local wiring rules. Then pick the slot pattern for how often wires leave the duct. Send the cable count and sizes for a recommendation.

Ask for a recommendation

How do I open or cut PVC cable duct?

The cover snaps on and lifts off by hand, so wiring can be added without removing the duct. Cut the duct and cover to length with a fine-tooth saw or duct cutter, and deburr the edge before laying in cables.

See DIN rails

Which LEIPOLE products are wiring duct or panel trunking?

Wiring duct, wire duct, slotted cable duct and panel trunking are names panel builders use for the same PVC channel. At LEIPOLE it is the 4R, 5R and 8R slotted duct from 25×25 mm to 100×120 mm and the R series solid-wall duct, in flame-retardant PVC rated UL94 V-0 and 2 m lengths.

Check technical documents

Does LEIPOLE supply building cable trunking or cable tray?

The LEIPOLE cable ducting range is flame-retardant PVC slotted and solid-wall wiring duct, used for routing wires inside control panels and electrical enclosures. For building trunking or cable tray, send the route, cable sizes and quantities so the team can confirm what can be supplied. In the panel, the duct works with LEIPOLE cable glands, cable entry plates, cable clamps and DIN rails.

See panel cable management