LEIPOLE Certifications
Shanghai Leipold Electric Co., Ltd. manufactures electrical enclosure accessories and thermal management products certified for the European, North American and international markets. This page lists our complete certificate register — 55 certificates currently in force, covering terminal blocks, busbar systems, filter fans and roof ventilators, enclosure heaters, thermostats, control transformers, cabinet lights, cable glands and enclosure air conditioners.
Certificates are issued by TÜV Rheinland LGA Products GmbH, Ente Certificazione Macchine Srl, UL Solutions and CTI Certification. Copies of any certificate and the corresponding test reports are available to customers, distributors and specifiers on request.
Management System Certification
ISO 9001:2015
Quality Management System
- Certificate No.
- 04126Q00268R801
- Standard
- GB/T 19001-2016 / ISO 9001:2015
- Valid
- 2026-06-17 to 2029-06-16
- Certification body
- CTI Certification Co., Ltd. (CNAS C041-M)
ISO 14001:2015
Environmental Management System
- Certificate No.
- 04126E00133R301
- Standard
- GB/T 24001-2016 / ISO 14001:2015
- Valid
- 2026-08-22 to 2029-08-21
- Certification body
- CTI Certification Co., Ltd. (CNAS C041-M)
Certified scope
Design and production of control transformers; production of electrical connectors, fans, and accessories for high and low voltage cabinets (within the scope of administrative licensing).
Production site: No.1569 Siyi Road, Jiading, Shanghai, P.R. China. Both certificates can be verified at cti-cert.com or through the Certification and Accreditation Administration of the People’s Republic of China at cnca.gov.cn.
CE Certification — TÜV Rheinland 27 certificates
Certificates of Conformity to the Low Voltage Directive (EU) 2014/35, issued by TÜV Rheinland LGA Products GmbH, Nürnberg. These certificates carry no fixed expiry date; they remain valid until the product construction or the referenced standard changes.
| Product | Models covered | Certificate No. | Standard / Directive | Issued | Valid until |
|---|---|---|---|---|---|
| Terminal Blocks — JUK Series | JUK2.5N/-BU, JUK2.5B, JUK3N, JUK5N, JUK6N, JUK10N, JUK16N, JUK35N, JUKH50, JUKH95, JUKH150, JUKH240, JUKK3/5, JUKK5-PV, JUKKB-3/-5, JUK5-MTK-P/P (4–240mm²) | AN 50729551 0001 | LVD 2014/35/EU · EN 60947-7-1 | 2026-06-05 | No expiry date stated |
| Terminal Blocks — JPT Series | JPT1.5, JPT2.5, JPT4, JPT6, JPT10 and -BU/-QU/-TW/TB/PV variants (1.5–10mm²) | AN 50729564 0001 | LVD 2014/35/EU · EN 60947-7-1 | 2026-06-05 | No expiry date stated |
| Terminal Blocks — JST Series | JST1.5, JST2.5, JST4, JST6 and -BU/-QU/-TW/-PE/TB variants (1.5–10mm²) | AN 50729559 0001 | LVD 2014/35/EU · EN 60947-7-1 | 2026-06-05 | No expiry date stated |
| Terminal Blocks — JSAK / JXB Series | JSAK2.5EN–JSAK70/35, JXB-2.5/35–JXB-70/35, JDK4QV/35, JDK4Q/35, JWTL6/1, JWTL6/1STB, JXB-4/35 S1/S1Z (2.5–70mm²) | AN 50729576 0001 | LVD 2014/35/EU · EN 60947-7-1 | 2026-06-05 | No expiry date stated |
| Power Distribution Blocks — UK Series | UK Series (35 / 50mm², Ith 100 / 160A, Ui 500 / 600V) | AN 50665461 0001 | LVD 2014/35/EU · EN 60947-7-1:2009 | 2025-03-05 | No expiry date stated |
| Power Distribution Blocks — UKK Series | UKK Series (16 / 35 / 120mm², Ith 80 / 250 / 500A, Ui 690V) | AN 50665465 0001 | LVD 2014/35/EU · EN 60947-7-1:2009 | 2025-03-05 | No expiry date stated |
| Power Distribution Blocks — UKK6 Series | UKK6 Series (10 / 16 / 35 / 50 / 70 / 95mm², Ith 63–600A, Ui 690V) | AN 50665562 0001 | LVD 2014/35/EU · EN 60947-7-1:2009 | 2025-03-05 | No expiry date stated |
| Power Distribution Blocks — UHTT Series | UHTT Series (70 / 120mm², Ith 160 / 250A, Ui 690V) | AN 50665553 0001 | LVD 2014/35/EU · EN 60947-7-1:2009 | 2025-03-05 | No expiry date stated |
| Busbar System — LP25 to LP80 | LP25A45/A54, LP32A45/A54/A63/A81, LP63A54/A63/A81, LP80A20/A54/A72 (25–80A, 690VAC) | AN 50713680 0001 | LVD 2014/35/EU · EN IEC 61439-1:2021 | 2026-02-12 | No expiry date stated |
| Busbar System — LP100 to LP630 | LP100A72/77, LP160A90/91, LP200A108, LP250A105/106/109, LP400A140/184, LP500A185, LP570/580/630A140/184 (100–630A) | AN 50713681 0001 | LVD 2014/35/EU · EN IEC 61439-1:2021 | 2026-02-12 | No expiry date stated |
| Busbar System — LP300 to LP800 | LP300A54, LP440A81, LP460A135, LP560A135/153, LP800A135/153 (300–800A, 690VAC) | AN 50713682 0001 | LVD 2014/35/EU · EN IEC 61439-1:2021 | 2026-02-12 | No expiry date stated |
| Enclosure Heaters — JRQ15 to JRQ150 | JRQ15, JRQ30, JRQ45, JRQ60, JRQ75, JRQ100, JRQ150 | AK 50722674 0001 | LVD 2014/35/EU | 2026-05-09 | No expiry date stated |
| Enclosure Heaters — JRQ250 / JRQFS Series | JRQ250, JRQ400, JRQFS200, JRQFS400, JRQFS650BA, JRQFS800BAT, JRQFS1000BAT | AK 50722676 0001 | LVD 2014/35/EU | 2026-05-09 | No expiry date stated |
| Fan Heaters — JRQFM Series | JRQFM100BA, JRQFM150BA, JRQFM200BA, JRQFM300BA, JRQFM300BAP | AK 50722680 0001 | LVD 2014/35/EU | 2026-05-09 | No expiry date stated |
| Thermostats — JWT / JSK Series | JWT6011, JWT6011F, JWT6011R, JWT6012, JSK0011F, JSK0011R, JSK0012, JSK0010R | AK 50722645 0001 | LVD 2014/35/EU | 2026-05-09 | No expiry date stated |
| EC Fan Speed Controller — LP17251 | LP17251-5.0, LP17251-5.1, LP17251-6.0, LP17251-6.1 | AK 50722657 0001 | LVD 2014/35/EU | 2026-05-09 | No expiry date stated |
| Temperature & Humidity Controller | JWT6013, JSK0013, JSK0014 | AK 50722658 0001 | LVD 2014/35/EU | 2026-05-09 | No expiry date stated |
| Single-phase Control Transformer — JBK5 Series | JBK5- Series | AN 50643205 0001 | LVD 2014/35/EU | 2024-09-23 | No expiry date stated |
| Single-phase Control Transformer — JBK5 Series, extended ratings | JBK5- Series (extended ratings) | AN 50647833 0001 | LVD 2014/35/EU | 2024-09-23 | No expiry date stated |
| Three-phase Isolating Transformer — SG Series | SG- Series | AN 50643221 0001 | LVD 2014/35/EU | 2024-09-23 | No expiry date stated |
| Axial Fan Motor (AC) | F2E- Series, F3E- Series, F5E- Series | AN 50679384 0001 | LVD 2014/35/EU · EN 60034-1 / -5 | 2025-07-09 | No expiry date stated |
| Centrifugal Fan Motor — xFLW Series (AC) | xFLW Series | AN 50679423 0001 | LVD 2014/35/EU · EN 60034-1 / -5 | 2025-07-09 | No expiry date stated |
| Axial Fan Motor (DC) | F2E- Series | AK 50679382 0001 | LVD 2014/35/EU · EN 60034-1 / -5 | 2025-07-08 | No expiry date stated |
| Filter Fan Motor — FB98 Series (AC) | FB98 Series | AN 50703474 0001 | LVD 2014/35/EU · EN 60034-1 / -5 | 2025-11-24 | No expiry date stated |
| Filter Fan Motor — FKL55 / 66 / 99 (AC) | FKL55 Series, FKL66 Series, FKL99 Series | AN 50703458 0001 | LVD 2014/35/EU · EN 60034-1 / -5 | 2025-11-24 | No expiry date stated |
| Filter Fan Motor — FKL55 / 66 / 99 (DC) | FKL55 Series, FKL66 Series, FKL99 Series | AK 50703316 0001 | LVD 2014/35/EU · EN 60034-1 / -5 | 2025-11-24 | No expiry date stated |
| Roof Ventilator Motor — F2Ex-y-DSP / DVP | F2Ex-y-DSP Series, F2Ex-y-DVP Series | AN 50703570 0001 | LVD 2014/35/EU · EN 60034-1 / -5 | 2025-11-24 | No expiry date stated |
CE Certification — Ente Certificazione Macchine 18 certificates
Voluntary third-party CE verification issued by Ente Certificazione Macchine Srl, Italy, covering the Low Voltage Directive 2014/35/EU and the EMC Directive 2014/30/EU. Each certificate carries a five-year validity.
| Product | Models covered | Certificate No. | Standard / Directive | Issued | Valid until |
|---|---|---|---|---|---|
| Thermostats — JWT / JSK Series | JWT6011, JWT6011F, JWT6011R, JWT6012, JWT6013, JSK0011F, JSK0011R, JSK0012, JSK0013 | 0H220915.SLEQQ66 | LVD 2014/35/EU + EMC 2014/30/EU · EN 60730-1 / -2-6 | 2022-09-15 | 2027-09-14 |
| Transformers — Full Range | JBK3, JBK4, JBK5, JBK6, JBK7, LDZB, DZD, JSZ, JSG, SG, SGC, LSZB, DG | 0H230216.SLE0C53 | LVD + EMC · EN IEC 61558-1:2019 / EN 61558-2-4 | 2023-02-16 | 2028-02-15 |
| Enclosure Heaters | See certificate annex (complete JRQ range) | 0H230605.SLEDN27 | LVD + EMC · EN IEC 60519-1:2020 / EN 60519-2 | 2023-06-05 | 2028-06-04 |
| Power Distribution Blocks | See certificate annex | 0H230605.SLEDN28 | LVD + EMC · EN IEC 60947-1:2021 / EN 60947-7-1:2009 | 2023-06-05 | 2028-06-04 |
| Busbar Terminals | A5x25-11K~25K, B3x17-5K/7K/10K, C5x15-5K/7K/10K, D8x12-4K~12K, E6x8, E8x12, F9x14, H9x19-26K/50K, E/H8x12, E/H6x8 | 0H230605.SLEDN29 | LVD + EMC · EN IEC 61439-1:2021 | 2023-06-05 | 2028-06-04 |
| Cable Glands | See certificate annex | 0H230605.SLEDN23 | LVD + EMC · EN 62444:2013 | 2023-06-05 | 2028-06-04 |
| Filter Fans — FK66 / FK77 / FK89 / FK99 Series | FK6627.300, FK6628.024/115/230/.300, FK7726.115/230/.300, FK8921~FK8926.024/115/230/.300, FK99 Series, etc. | 0P251118.SLESQ30 | LVD + EMC · EN IEC 60335-1:2023 / 60335-2-80:2024 / EN 62233 / 55014 | 2025-11-18 | 2030-11-17 |
| Roof Ventilators — DP Series | F2E190-230-DP, F2E220-230-DP, F2E225-230-DP, F2E190-380-DP, F2E220-380-DP, F2E225-380-DP | 0P251118.SLESQ31 | LVD + EMC · EN IEC 60335-1 / 60335-2-80 / EN 62233 / 55014 | 2025-11-18 | 2030-11-17 |
| Cabinet Lights & Accessories — LZ / LS Series | LZ-4138.10/14/18/30-1/-2, LZ5013.600/800/1000-1/-2, LS5013.1000-1, LZ4315 Series, etc. | 0P251118.SLESQ32 | LVD + EMC · EN IEC 60598-1:2024 / 60598-2-1 / 55015 / 61547 | 2025-11-18 | 2030-11-17 |
| Terminal Accessories — Insertion Bridges & Jumpers | FBI2-5/15~FBI10-15, FB10-JRTK/S, JSAK2.5Q10~JSAK70Q10, DK4Q10, JUSB2-JRTK/S, JXB-2.5L~JXB-35L, etc. | 0P251118.SLESQ33 | LVD 2014/35/EU · EN 60947-7-1:2009 | 2025-11-18 | 2030-11-17 |
| Terminal Blocks — UN / UD Series | JUK5-HESI, JUK10-DREHSI, UN10K~UN50K, UN10~UN200BW/BK-3P, UN10L~UN50L, UN100, UN150, UD15/L/F, etc. | 0P251118.SLESQ34 | LVD 2014/35/EU · EN 60947-7-1:2009 | 2025-11-18 | 2030-11-17 |
| Terminal Accessories — Markers, End Brackets & Covers | ZB4/5/6/8/10, DEK5, DEK6, JAKG4/16/35 (BU/GNYE/BK), AB/SS, AB/2SS, NS-1/2/5, TSTW, JKLM-A, B1, B2, SCHT3S, SCHT5S, JUBE/D, E/JMK1, E/JUK, E/AL-NS35, JEW15/35, JXB-GD15, etc. | 0P251118.SLESQ35 | LVD 2014/35/EU · EN 60947-7-1:2009 | 2025-11-18 | 2030-11-17 |
| Terminal Accessories — Additional Range I | See certificate annex | 0P251118.SLESQ36 | LVD 2014/35/EU · EN 60947-7-1:2009 | 2025-11-18 | 2030-11-17 |
| Terminal Accessories — Additional Range II | See certificate annex | 0P251118.SLESQ39 | LVD 2014/35/EU · EN 60947-7-1:2009 | 2025-11-18 | 2030-11-17 |
| Busbar Frames & Busbar Connection Terminals | LPSU1-A~LPSU4-A, LPSU1-ABF~LPSU4-ABF, LPSU3-E, LPSU1-BBF, LPSU3-BBF, SU201~SU209, SU300, LP32A0405/0410, LP80A1605/1610, etc. | 0P251118.SLESQ37 | LVD 2014/35/EU · EN 61439-6:2012 | 2025-11-18 | 2030-11-17 |
| Cabinet Lights & Accessories — Supplementary Range | See certificate annex | 0P251118.SLESQ38 | LVD + EMC · EN IEC 60598-1:2024 / 60598-2-1 / 55015 / 61547 | 2025-11-18 | 2030-11-17 |
| Busbar Covers | A1025, A1028, A1069, A1136, A1223, A1229, A1242~A1245, A1249, A1250, A1252, A1395, A1397, A1554~A1559, A1566, A1596, A1608, A1756, A1990 | 0P251118.SLESQ40 | LVD 2014/35/EU | 2025-11-18 | 2030-11-17 |
| Fuse Switch Disconnectors | LPA3216-100A, LPA3600-160A, LPA3601-250A-1/2, LPA3602-400A-1/2, LPA3603-630A-1/2 | 0P251118.SLESQ41 | LVD 2014/35/EU · EN IEC 60947-3:2021 | 2025-11-18 | 2030-11-17 |
UL / North America 5 certificates
UL Recognized Component certificates for the North American market, evaluated to UL and CSA standards. UL certificates carry no expiry date; validity is maintained through UL Follow-Up Service factory inspections.
| Product | Models covered | Certificate No. | Standard / Directive | Issued | Valid until |
|---|---|---|---|---|---|
| Electric Fans — Recognized Component | 133FLW2/3, 170FLW1/2/3, 190FLW1/2/3, 220FLW2/3, 225FLW2/4, 250FLW2/4, 280FLW2, F2E-120B/S, F2E-150B/S, F2E-162B, F2E-170B, F2E-20772B, F2E-250/.V, F2E-260B, F2E-320B (115 / 230 / 380V) | UL-US-2420321-0 · File E324860 | UL 507 Ed.10 · CSA C22.2 No.113 | 2024-05-24 | Maintained by Follow-Up Service |
| Terminal Blocks — UK Series | UK207, UK407, UK411, UK412, UK415 | UL-US-2575054-0 · File E334233 | UL 1059 Ed.6 (XCFR2 Terminal Blocks – Component) | 2025-07-01 | Maintained by Follow-Up Service |
| Terminal Blocks — UKK Series | UKK80A, UKK125A, UKK160A, UKK160A-8K, UKK250A, UKK400A, UKK500A | UL-US-2575056-0 · File E334233 | UL 1059 Ed.6 (XCFR2 Terminal Blocks – Component) | 2025-07-02 | Maintained by Follow-Up Service |
| Fan Motors — Impedance / Thermally Protected | Motors used in the F2E and FLW fan series | File E539716 | UL 1004-1 / -2 / -3 · CSA C22.2 No.100 / 77 | 2024-04-05 | Maintained by Follow-Up Service |
| Witnessed Test Data Program (WTDP) | Leipole test data accepted by UL under the WTDP programme (Project 4791176808) | UL Certificate of Achievement | UL 1004-1 / -2 / -3 · UL 507 Ed.10 · CSA C22.2 No.100 / 77 / 113 | 2024-03-21 | — |
Other CE Certificates & Declarations 3 certificates
Third-party declarations of conformity and EU Declarations of Conformity issued under the manufacturer’s own responsibility in accordance with Annex IV of Directive 2014/35/EU.
| Product | Models covered | Certificate No. | Standard / Directive | Issued | Valid until |
|---|---|---|---|---|---|
| Enclosure Air Conditioners | LP500N-1, LP1000N-1, LP1500N-1, LP3000N-1, LP4000N-1 (230V~, 50/60Hz, 440W, cooling capacity 1000W) | GTSC20240612021-1-01 | LVD 2014/35/EU · EN IEC 60335-2-40:2023 / EN 60335-1 / EN 62233 | 2024-07-10 | — |
| Filter Fans FKL55 / 66 / 99 — EU Declaration of Conformity | FKL55 / FKL66 / FKL99 Series (representative models FKL5525-200.115 / FKL5526.230) | LEIPOLE-DoC-FKL55/66/99-2026-01 | LVD 2014/35/EU Annex IV · EN 60034-1 / EN 60034-5; referencing TÜV AN 50703458 0001 | 2025-11-30 | — |
| LED Position Indicators — 127-22WF Series | 127-22WFD (withdrawable position), 127-22WFG (open / closed position), 127-22WFN (earthing position); Ø22mm panel cut-out, ≤20mA, 2.5kV/1min | LPCE222012 Rev.01 | LVD + EMC + RoHS · EN IEC 60947-1 / EN 60947-5-1 / EN 60073 / EN IEC 61000-6-2 / -6-3 | — | — |
Verifying our certificates
Every certificate listed above can be checked independently with the issuing body. We encourage customers carrying out supplier qualification to do so:
- TÜV Rheinland — look up the registration number (format
AN / AK 5xxxxxxx 0001) in TÜV Rheinland Certipedia. - UL Solutions — search the UL file number (
E324860,E334233,E539716) in UL Product iQ. - Ente Certificazione Macchine — verify the certificate number at entecerma.it.
- CTI Certification — verify the ISO certificate numbers at cti-cert.com or cnca.gov.cn.
Request certificate copies and test reports
Certificate register last updated 13 September 2026.