- Enclosure thermal management. Reliable connections. Practical solutions.
- Customer Portal ↗
Centrifugal fans
ENGINEERING SUPPORT
Find the right fit.
Talk to our team about product selection and your application.
Contact technical supportOverview
Key advantages
Air duct design
Impeller structure optimization, delivery of air volume greatly improved, energy consumption reduced.
Strong static pressure output
Suitable for high resistance environment, filtration systems, ventilation ducts and etc.
Materials
Heavy duty PA6+GF (glass fiber reinforced nylon) or aluminum alloy impellers for excellent durability and high temperature resistance.
Dust and water proof
IP44 protection level, suitable for harsh industrial environments.
Automatic protection mechanism
With automatic recovery thermal protection. It improves the safety and reliability of the electric motor.
Noise free operation
Optimize the design of the fan structure and motor to reduce the running noise, provide a good working atmosphere.
Models & specifications

| wdt_ID | wdt_created_by | wdt_created_at | wdt_last_edited_by | wdt_last_edited_at | Model | Order number | Rated voltage | Air flow m³/h | Static pressure pa | Dimension mm |
|---|---|---|---|---|---|---|---|---|---|---|
| 37 | w3381121 | 17/01/2025 09:29 AM | w3381121 | 17/01/2025 09:29 AM | 133FLW2 | 2019.001 | 220V AC | 270 | 185 | 93.5*76.8 |
| 38 | 133FLW3 | 2019.002 | 380V AC | 330 | 240 | 93.5x76.8 | ||||
| 39 | 170FLW2 | 2019.003 | 220V AC | 450 | 275 | 175x69.1 | ||||
| 40 | 170FLW3 | 2019.004 | 380V AC | 450 | 275 | 175x69.1 | ||||
| 41 | 190FLW2 | 2019.005 | 220V AC | 570 | 325 | 190x72 | ||||
| 42 | 190FLW3 | 2019.006 | 380V AC | 1170 | 520 | 190x72 | ||||
| 43 | 220FLW2 | 2019.007 | 220V AC | 900/1002 | 420/520 | 221.5x76.8 | ||||
| 44 | 220FLW3 | 2019.008 | 380V AC | 900/1020 | 420/520 | 221.5x76.8 | ||||
| 45 | 225FLW2 | 2019.009 | 220V AC | 1200/1338 | 550/725 | 226x101.2 | ||||
| 46 | 225FLW3 | 2019.010 | 380V AC | 1200/1338 | 550/725 | 226x101.2 | ||||
| Model | Order number | Rated voltage | Air flow m³/h | Static pressure pa | Dimension mm |
Applications
Use areas of Leipole Centrifugal Fans series:
Manufacturing: These are used to cool electrical cabinets on the production line so as not to overheat and not let dust in.Automation:Ensure stable cooling and dust-proof for automation equipment.Power distribution: Stable operation of power distribution equipment under high temperature environment.Renewable resources:Used for solar and wind energy equipment cooling and dust control.
Electric vehicle charging station:
Avoid overheating of charging equipment, ensuring the charging process is both efficient and safe.
Basic knowledge
Centrifugal fan working principle:
In case the suction area has a narrow opening, there would be an increase in pressure and that in turns increases the velocity through an automatic adjustment.
The rotation of the impeller accelerates the air radially, and the shell guides the air into the exhaust duct to generate a higher wind pressure, so that the air can be delivered over a long distance.
Used to apply in the environment with high static pressure and large air volume.
Key parameters:
Air Flow: 570m³/h ~ 2670m³/h
Power Input: 3.5W 10W Static Pressure: 350Pa 750Pa
Power: 0.2kW ~ 1.5kW
Voltage: 220V / 380V, 50/60Hz
Noise Level: 56dB ~ 75dB (based on fan size and air volume)
IP Rating: IP44
Frequently asked questions
Q1: What are centrifugal fans and axial flow fans?
A1: Centrifugal fans are used for applications with high wind pressures, like filtration, duct ventilation, etc. Axial flow fans are used in low resistance heat dissipation scenarios, like cooling electrical cabinet.
Q2: Is it possible to customize the fan?
A2: Yes, we are able to customize centrifugal fan of different air volume, size and installation way according to the needs.
Q3: How much noise does Centrifugal Fans make?
A3: The Centrifugal Fans of Leipole are characterized by low-noise, (50~70dB) depending on the model and Air volume.
Q4: Can Centrifugal Fans be installed outdoors?
A4: Yes, our Centrifugal Fans have a high IP rating (IP44 for example) and is accordingly available for outdoor or harsh environment.
Q5: The volume and air pressure must be determined by the person using the machine.
A5: The air volume and air pressure are determined by the heat generation of the equipment and the ambient temperature. Just offer your requirements and our engineers will give suggestions accordingly.
Where are industrial blower fans commonly used?
Industrial blower fans are widely used in ventilation systems, dust collection, industrial cooling, and drying processes due to their high airflow and pressure capacity.
Is an AC centrifugal fan better for continuous airflow?
Yes, an AC centrifugal fan is ideal for continuous, stable airflow in HVAC systems, control cabinets, and enclosed environments where durability matters.
Why choose a backward curved centrifugal blower over a forward curved one?
A backward curved centrifugal blower is more energy-efficient, produces less noise, and handles higher static pressure—perfect for clean air applications.
How does an impeller fan improve ventilation efficiency?
An impeller fan enhances ventilation by generating strong, consistent airflow with minimal power. It’s essential in both axial and centrifugal fan designs.
What to consider when comparing centrifugal fan suppliers?
When choosing centrifugal fan suppliers, compare build quality, CFM ratings, voltage compatibility, certifications, and after-sales support to ensure long-term reliability.
Product inquiry
Related products
Related products
-

Low Profile Fan Filter 100m³/h (59CFM)Cabinet | FKL5523.230
View products -

Large Flow Filter Fan 1800m³/h (1060CFM) Industrial | FK9926.230-D
View products -

High Flow Cooling Fan 1050m³/h (618CFM) Cabinet | FK9926.115
View products -

Standard Filter Fan 195m³/h (115CFM) Electric Cabinet | FK9922.115
View item
Selection & support
Selecting LEIPOLE centrifugal fans
Use a centrifugal fan when the air path has high resistance.
When should I use a centrifugal fan instead of an axial fan?
When the air must pass dense filters, ducts or tightly packed equipment: a centrifugal fan builds much higher static pressure. LEIPOLE FLW centrifugal fans deliver 270 to 2580 m³/h at static pressures of 185 to 750 Pa, in 220 V and 380 V AC versions.
Compare axial fans →Where can I buy centrifugal fans in Singapore?
Send the LEIPOLE Singapore team the airflow and static pressure you need, the supply voltage (220 V or 380 V AC), quantity and destination. The FLW range runs from 133FLW2 to 355FLW4A, and the team will confirm the model against its fan curve.
Request a quotation →Is a blower fan the same as a centrifugal fan?
Usually, yes. In industrial and enclosure ventilation a blower fan is a centrifugal fan: the impeller draws air in along its shaft and throws it outwards at right angles, which builds more static pressure than an axial fan of similar size. The word is also used loosely for any fan that blows air. LEIPOLE also supplies EC centrifugal fans with speed control.
See EC centrifugal fans →